Stay Assured, Stay Secured Assurays: X-Ray QA, AERB Registration & Certification Stay Assured, Stay Secured Assurays: X-Ray QA, AERB Registration & Certification Stay Assured, Stay Secured Assurays: X-Ray QA, AERB Registration & Certification 0{{current_slide_index}}/0{{total_slide_count}}

Introducing Lead Free Radiation Shielding Tiles

Our Lead-Free Radiation Shielding Tiles and Bricks are specially designed to provide effective radiation protection without the use of toxic lead. Engineered using high-density, eco-friendly materials, they deliver equivalent shielding performance to conventional lead-based products while ensuring safety for both humans and the environment.

Available in various forms and different lead equivalence eg. 0.5 mm 1.0 mm 2.0mm.

Radiation Tiles Used In

Medical Imaging Centers

X-ray rooms, CT scan facilities, dental clinics

Radiation Therapy Units

Linear accelerators, oncology departments

Nuclear Medicine Labs

PET/CT, gamma camera installations

Industrial Radiography

NDT testing rooms, pipeline inspection sites

Protective Barriers & Enclosures

Walls, floors, ceilings, and mobile shields

AERB Type Approved X-Ray Machine

Portable x-ray Machine

Fixed X-ray Machine Various type 100ma, 300ma 500ma etc

Battery upgraded Portable X-ray Machines.

According to the guidelines given by Atomic Energy Regulatory Board, a legal mandate has been issued to get Room Layout Approval and Registration/License for all X Ray equipment installed in your institute. The heart of the Registration/Licensing process is the Quality Assurance done on every equipment installed.

What is Quality Assurance? It is a set of performance tests performed on a particular X Ray diagnostic equipment that verifies whether the Output Primary radiation and the Leakage Secondary Radiation is within tolerance limits specified by AERB. In addition to this, it also takes care of the image quality of the equipment.

One Stop AERB Solutions for Licensing & Quality Assurance Test

X-ray Machine

CT Scan Machine

Mammography

Dental Opg

Dental iopa

BMD/Dexa

C-Arm

Cathlab

CBCT

Industrial X-ray

What we do

Our Expertise and Strength

Strong Focus providing prompt service

Dedicated and BARC/AERB Certificate Staff.

Radiaton Shielding Products

AERB/BARC certified Lead free Aprons

Mobile Protective Barriers

AERB/BARC certified in Lead Gloves

Lead Goggles

Mobile Protective Barriers

Thyroid collar

Lead sheets

Lead doors

5K

HAPPY CLIENT

76

FACLTIESIES

18

YEARS

30

MACHINAERY

Radiation Protection & Shielding Products (Specifications)

Lead-Free Shielding Tiles

0.5 mm / 1.0 mm / 2.0 mm Pb equivalence; bismuth or tungsten composite; used for X- ray room wall lining.

Lead-Lined Gypsum Board / Wall Panel

Multi-layer gypsum board with 1 mm–3 mm Pb sheet backing for fixed X-ray barriers.

Lead-Free Shielding Bricks / Blocks

Reusable high-density polymer or tungsten composite bricks (4 g/cc–8 g/cc) for flexible shielding walls.

Lead Sheet (Rolled)

Pure lead sheets, 0.5 mm–3 mm thick, used behind walls, doors, and partitions for radiation protection.

Lead-Lined Door / Lead-Free Door

Wooden or steel door lined with 1 mm–3 mm Pb or equivalent composite; with leaded vision glass window.

Lead Glass (X-ray Viewing Window)

Optical-grade radiation protective glass with 1.5 mm–3.0 mm Pb equivalence; sizes up to 1000 × 800 mm.

Lead-Lined Glass Frame / Viewing Panel

Powder-coated steel frame with lead overlap joints; compatible with lead glass window installation.

Mobile Shield / X-ray Barrier Screen

Movable lead-lined panel with 1.5 mm–2 mm Pb eq. glass window for operator protection during exposure.

Lead Apron (Front or Wrap-Around)

0.25 mm / 0.35 mm / 0.5 mm Pb equivalence; lightweight lead-free or lead composite; vinyl-coated outer cover.

Thyroid Shield

0.5 mm Pb eq. protection collar with Velcro closure; used with lead apron.

Lead Gloves

0.25 mm / 0.5 mm Pb eq.; soft and flexible latex-free gloves for hand protection in fluoroscopy.

Lead Goggles / Leaded Eyewear

0.33 mm Pb eq. side-shielded glass lenses to reduce eye lens dose.

Lead Curtains / Ceiling Shields

Hanging lead-vinyl curtains (0.5 mm Pb eq.) for interventional radiology and cath-lab areas

Lead-Free Shielding Tiles

0.5 mm / 1.0 mm / 2.0 mm Pb equivalence; bismuth or tungsten composite; used for X- ray room wall lining.

Lead-Lined Gypsum Board / Wall Panel

Multi-layer gypsum board with 1 mm–3 mm Pb sheet backing for fixed X-ray barriers.

Lead-Free Shielding Bricks / Blocks

Reusable high-density polymer or tungsten composite bricks (4 g/cc–8 g/cc) for flexible shielding walls.

Lead-Lined Door / Lead-Free Door

Wooden or steel door lined with 1 mm–3 mm Pb or equivalent composite; with leaded vision glass window.

Lead Curtains / Ceiling Shields

Hanging lead-vinyl curtains (0.5 mm Pb eq.) for interventional radiology and cath-lab areas

Lead Glass (X-ray Viewing Window)

Optical-grade radiation protective glass with 1.5 mm–3.0 mm Pb equivalence; sizes up to 1000 × 800 mm.

Lead-Lined Glass Frame / Viewing Panel

Powder-coated steel frame with lead overlap joints; compatible with lead glass window installation.

Mobile Shield / X-ray Barrier Screen

Movable lead-lined panel with 1.5 mm–2 mm Pb eq. glass window for operator protection during exposure.

Lead Apron (Front or Wrap-Around)

0.25 mm / 0.35 mm / 0.5 mm Pb equivalence; lightweight lead-free or lead composite; vinyl-coated outer cover.

Thyroid Shield

0.5 mm Pb eq. protection collar with Velcro closure; used with lead apron.

Lead Gloves

0.25 mm / 0.5 mm Pb eq.; soft and flexible latex-free gloves for hand protection in fluoroscopy.

Lead Goggles / Leaded Eyewear

0.33 mm Pb eq. side-shielded glass lenses to reduce eye lens dose.

Lead Curtains / Ceiling Shields

Hanging lead-vinyl curtains (0.5 mm Pb eq.) for interventional radiology and cath-lab areas

Lead Sheet (Rolled)

Pure lead sheets, 0.5 mm–3 mm thick, used behind walls, doors, and partitions for radiation protection.

Before & After Installation of Tiles

Radiation Tools

01
Survey Meter

Measures ambient radiation dose rate in X-ray and nuclear areas.

02
KVP Meter

Checks X-ray tube voltage and exposure consistency.

03
mA / mAs Meter

Measures tube current and exposure time for radiographic QA.

04
Phantom Test Object

Used for image quality and constancy testing of X-ray systems.

Common Features for All Models

AERB Approved and BIS Certified

Inbuilt safety interlocks and protection circuits

Compact design with ergonomic control panel

Stable and consistent X-ray output

Compatible with CR & DR systems

Service and spare support available PAN India

AERB Approved and BIS Certified

Inbuilt safety interlocks and protection circuits

Compact design with ergonomic control panel

Stable and consistent X-ray output

Compatible with CR & DR systems

Service and spare support available PAN India

High Frequency X-Ray Generator

The High Frequency X-Ray Generator is the core power source of modern X-ray imaging systems, designed to deliver stable, high-quality X-ray output with precise control and maximum efficiency.

Built using advanced inverter technology, this generator ensures superior image quality, reduced patient dose, and long equipment life, making it ideal for all medical imaging and industrial radiography applications.

Key Features

High Frequency Inverter Technology (40–150 kHz):

Provides consistent X-ray output and eliminates image artifacts caused by voltage ripple.

Compact & Lightweight Design:

Saves installation space and improves system mobility.

High Efficiency & Low Power Loss

Converts AC power to high-frequency DC with over 95% efficiency.

Precise kV & mA Control

Digital microprocessor ensures accurate exposure settings for better imaging results.

Superior Image Quality

Stable high-voltage output ensures sharp, noise-free diagnostic images.

Built-in Safety Protections

Overload, over-voltage, and over-temperature protection systems ensure safe operation.

Precise kV & mA Control

Digital microprocessor ensures accurate exposure settings for better imaging results.

Superior Image Quality

Stable high-voltage output ensures sharp, noise-free diagnostic images.

Built-in Safety Protections

Overload, over-voltage, and over-temperature protection systems ensure safe operation.

High Frequency Inverter Technology (40–150 kHz):

Provides consistent X-ray output and eliminates image artifacts caused by voltage ripple.

Compact & Lightweight Design:

Saves installation space and improves system mobility.

High Efficiency & Low Power Loss

Converts AC power to high-frequency DC with over 95% efficiency.

Mammography Imaging & Analysis Software

The Assurays Mammography Software is a next-generation diagnostic platform designed to support breast cancer screening and diagnosis with unmatched accuracy, speed, and image clarity.

It integrates advanced AI-based image analysis, DICOM compatibility, and workflow automation to enhance radiologist productivity and diagnostic confidence.

Book An Appointment